Peppers Cable Glands

Peppers Cable Glands USA

 

 

 

 

 

 

 

For details and more information please e-mail us, or call 1-949-306-6899.

 

Who is Peppers Cable Glands?

For over 68 years, Peppers Cable Glands has been involved in the manufacture and sale of Cable Glands, giving the company a wealth of experience and expertise within the industry.

Operating from its UK base in Surrey, Peppers Cable Glands runs a satellite manufacturing system using group companies situated in the North of England. This provides an assured supply chain and when paired with their global distribution network, results in on-time deliveries. We believe quick deliveries are only part of the service.

“It’s all about the complete experience,” We aim to give our customers excellent service not just in terms of our quick deliveries but from when the initial contact is made throughout the quotation, ordering, and expediting process.

Peppers’ customers can be sure that they are getting accurate advice and if we are unable to meet your requirements we will inform you. We don’t bend the truth to secure orders. Peppers’ simply does not promise what it cannot deliver.

Peppers operates a quality management system, approved to ISO 9001:2008 and an Environmental System approved to ISO14001:2004. All employees are trained to recognize what it takes to meet these standards and staff assessments are undertaken regularly to ensure that the highest levels of customer service are maintained at all times.

Peppers’ has an extensive range of international approvals incorporating ATEX, IECEx, UL, CSA, GOST, INMETRO & NEPSI as well as marine approvals by ABS (American Bureau of Shipping), RMRS (Russian Maritime) & Lloyds Register. Our range of approved products are designed and tested for use in Ex d, Ex e, Ex nR and Ex t hazardous area protection concepts.

Peppers’ range of glands incorporate some unique engineering features: The CR gland for armored cable features a single orientation clamping system, “CROCLOCK®” allowing the clamping of all armor types with no mistakes being possible during installation. The advertising slogan “No reversible Components – No Mistakes” sums up this benefit. Due to ingenious design features, Deluge is achieved without the use of additional sealing devices.

Peppers barrier glands incorporate unique features that reduce installation times by using the Peppers T-1000 compound, which enables the conductors to be terminated within the equipment after one-hour. At four hours, the compound chamber may be inspected and the equipment can be energized. Our innovative barrier chamber provides a cable acceptance that is on average 17% larger than other barrier gland designs allowing the use of smaller glands thereby significantly reducing cost.

Glands can be supplied in various materials including brass, aluminum, stainless steel and polyamide. We offer plating options for corrosion protection, including nickel, tin, and zinc. Peppers also supply accessories, which include a comprehensive range of certified thread adaptors, reducers, stopping plugs and breathers.

Peppers’ Engineering Team are constantly striving to improve the quality of our range whilst continually working to design and develop new and innovative products.

Peppers Cable Glands Ltd…
“a refreshing attitude to manufacturing”

Ex d / Ex e Glands

Click here to download the full catalogue (7.4MB)

Elastomeric Seal Cable Glands
For use in Zone 1, Zone 2, Zone 21, Zone 22, Gas Group IIA, IIB and IIC
Gland Type
Outer SealInner SealLead OptionArmour ClampCertificationIP RatingPage No
C R-****
ticktickticktick
Croclock®
Exd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
Page 1.1.0
1.1.0
E****F*
ticktickticktickExd/Exe/ExnR
Class 1 Div 2
IP66, 68
NEMA 4X
Page 1.2.0
1.2.0
C****E*
tickcrosscrosstickExe
Class 1 Div 2
IP66
NEMA 4X
Page 1.3.0
1.3.0
A*L*F
tickcrosstickcrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
Page 2.1.0
2.1.0
A*LDS*F
tickx2crosstickcrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
Page 2.2.0
2.2.0
A*LC**F
(Conduit)
tickcrosscrosscrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
Page 2.3.0
2.3.0
Flat Cable Glands & Nylon Cable Glands
For use in Zone 1, Zone 2, Zone 21, Zone 22, Gas Group IIA, IIB and IIC
Gland Type
Outer SealInner SealLead OptionArmour ClampCertificationIP RatingPage No
E8X*F
Flat CableFlat Cablecrosstick
Braid
Exd/Exe/ExnRIP66, 68Page 3.1.0
3.1.0
A8*F
Flat CablecrosscrosscrossExd/Exe/ExnRIP66, 68Page 3.2.0
3.1.0
PF
(Nylon)
tickcrosscrosscrossExeIP66, 68Page 3.2.0
3.2.0

 

Key

tickcross

 

Peppers Barrier Glands

Click here to open the Peppers T1000 Barrier Compound Technical Data Sheet [TDS]
Click here to open the T1000 Barier Compound afety Data Sheet [SDS]

Click here to download the full catalogue

Barrier Glands
For use in Zone 1, Zone 2, Zone 21, Zone 22, Group I Mining
Gas Group IIA, IIB and IIC and Dust Groups IIIA, IIIB, IIIC
Gland Type
Outer SealInner SealLead OptionArmour ClampCertificationIP RatingPage No
CR-C
ticktick
Compound
ticktick
Croclock®
Exd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
pdf
4.1.0
CR-X
crosstick
Compound
tickcrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
pdf
4.2.0
CR-U
ticktick
Compound
tickcrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
pdf
4.2.1
CR-S
crosstick
Compound
crosscrossExd/Exe/ExnR
Class 1 Div 2
Deluge
IP66, 68
NEMA 4X
pdf
4.3.0
Barrier Glands
For use in Class I Div 1 & 2, Zone 1, Zone 2, Zone 21, Zone 22, Group I Mining
Gas Group IIA, IIB and IIC and Dust Groups IIIA, IIIB, IIIC
Gland Type
Outer SealInner SealLead OptionArmour ClampCertificationIP RatingPage No
UL-C
ticktick
Compound
crosstick
Croclock®
Class I Div 1
ABCD
Exd/Exe/ExnR
NEMA 4X
Deluge
IP66, 68
pdf
4.4.0
UL-U
ticktick
Compound
crosscrossClass I Div 2
ABCD
Exd/Exe/ExnR
NEMA 4X
Deluge
IP66, 68
pdf
4.5.1

Key

tickcross

People choose Peppers Cable Glands because we take pride in delivering…

  • Quality Products
  • Accurate Advice
  • Outstanding Service

With over 68 years of experience, Peppers Cable Glands Ltd has a unique and refreshing attitude to UK manufacturing.